Maintain Annotation Orientation on Revit Lighting Fixtures and Electrical Equipment

For reasons that are still unknown to me, Revit does not allow, to date, the use of the setting "Maintain Annotation Orientation" on two family categories: lighting fixtures and electrical equipment.



This is particularly painful for the electrical discipline because so much of the documentation on plans is symbolic. Perhaps the thought process was that since light fixtures and electrical equipment is usually more than 6 inches in size that the use of nested annotation symbols wasn't necessary.

Or maybe the programmers just didn't catch that those two family categories acted differently and haven't heard the howls of complaint from the industry?

The Usual Approaches


Regardless of the reasons, it has left the MEP industry in a state where workarounds are needed in order to properly annotate plans. I'm talking about true annotation symbols and not just using symbolic lines in the model family. Symbolic lines won't scale automatically based on the scale of the view. For example, you cannot do what is shown below on that single instance of the family just using symbolic lines.



In order to show that wall mounted light sconce symbol on plans you have the following workarounds:
  1. Just place annotation families and not model families
  2. Forget using the lighting fixture category and use lighting devices instead
  3. Use a shared intermediate nested face-based family to orient the nested annotation family as described by Jose Fandos
Opinions on option 1: Why are you drafting in Revit? You might as well do the project in AutoCAD. Oh, and try to circuit those annotation families...

Opinions on option 2: Seems like a simple solution, until you consider the "I" in BIM. Good luck getting your lighting fixture schedule to work correctly. Or getting renderings using the photometrics for those wall sconces. Or isolating the lighting fixtures on the project.

Opinions on option 3: This approach works. You will have to filter out the shared intermediate family to avoid seeing it in your schedules which is easy enough. However, I've also seen plenty of cases where the intermediate family is considered by Revit to be not hosted to a face and therefore showing in the Reconcile Hosting dialog. I've found that this approach confuses my designers when hosting goes wrong.



Another issue is that the intermediate family instance in the host family is not visible in the family editor so family maintenance by someone other than the family author can be tricky.

Yet Another Approach


I recently read a post by Brian Mackey about creating a vertical face-based family template. The approach is that you create a family template started from a wall-based family template and convert it to face-based using Batch Copy/Monitor. The reason that Brian did this was so that the orientation of the hosting face in the family editor look like a wall. After I read the post I wondered what would happen if I placed a nested annotation family in a family created by that new template.

I was pleased to see that nested annotation families are visible! And without the need to use a shared intermediate family. "And there was much rejoicing."

Now, before you go crazy and start using this approach, I do need to caution you that when you use the process described by Brian, your resulting families will lose the use of the Default Elevation parameter. You will still be able to use the Elevation parameter to change the elevation of the element, but you cannot assign a default elevation. Sadly, the Default Elevation parameter is listed in the element's instance properties so this could potentially confuse your designers.



You will have to decide if the loss of the assignment of a default elevation is worth the direct use of a nested annotation family in your lighting fixtures and electrical equipment.

Conclusion


The majority of my wall-based lighting fixture and electrical equipment families that need annotation symbols currently use Jose's approach. However, the reconcile hosting issue is severe enough that I will be going back through those families and converting them to a template based on Brian's approach, despite the default elevation issue.

I will finally have direct nested annotation families in my lighting fixtures and electrical equipment even without the Maintain Annotation Orientation parameter.

Autodesk, the Autodesk logo, AutoCAD, Navisworks, and Revit are registered trademarks or trademarks of Autodesk, Inc., and/or its subsidiaries and/or affiliates in the USA and/or other countries.

5 comments:

  1. Use Default Elevation as height parameter is one way to have default elevation, but Elevation will be confused.

    ReplyDelete
  2. Furthermore, ask past clients the amount they were charged for comparative project needs. This guarantees you'll be guaranteed a reasonable cost from your electrician.
    voorhees nj electrical contractors

    ReplyDelete
  3. This comment has been removed by the author.

    ReplyDelete
  4. This brilliant yellow chunk of light has been seen close to the railroad tracks since the mid 1900's. https://www.insignis.ro/corpuri-de-iluminat/

    ReplyDelete
  5. A firm like Nexus Automation can produce exactly what you want in the best quantities as your group works to deliver its products to market. You wouldn’t wish to waste money investing within the incorrect items or spend priceless time on a posh course of when you could be focusing in your core enterprise. By hiring a machine shop, skilled machinists will fulfill your precision machining needs for you. First of all, they feature a variety of CNC machining quality settings, which—in contrast to 3D printers—can create prototypes with rougher designs in some parts of the material and smooth designs in others. 3D printers may produce distorted products in high heat, and as such, they can't assure precision in hotter conditions.

    ReplyDelete